The KIP-1 product is a BLH NOBEL off-center tensiometric system used to avoid product breakage and machine jams with consequent production stops. Off-center load cells find many applications, for example in textile machines, converting, plastic films and winders. KIP-1 guarantees a high torsion resistance against torque forces and overload and it is easy to install. PWS: 46/2012
Technical Specifications in PDF
| Rated load RL: 10, 20 kN |
| Combined error: ±0.1 % RO |
| Repeatability: 0.02 % RO |
| Safe overload: 100 % RL |
| Ultimate overload: 200 % RL |
| Material: Stainless steel |
| Degree of protection: IP 67 |
| Temperature range: -40 ÷ + 80 (+ 100 optional) °C |
| Temperature effect on zero balance: ±0.005 % RO/°C |
| Temperature effect on output: ±0.005 % output/ °C |
| Rated output RO: 1.020 mV/V |
| Zero balance: ±2 % RO |
| Insulation resistance: >4 G Ohm |
| Input resistance: 382 ±3 Ohm |
| Output resistance: 350 ±3 Ohm |
| Recommended input: 10 Vdc/ac |
| Maximum supply voltage: 18 Vdc/ac |
| Rated output tolerance: ±0.25 |